Fmi V300 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Pumpen Fmi V300 herunter. FMI V300 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 7
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
IN-V300-08
1
V300 SET UP INSTRUCTIONS
FOR ADDITIONAL REFERENCES SEE H431 AND Q431
Before using any Fluid Metering, Inc. product read the following safety instructions
as well as specific product specifications and operating instructions.
Warning! Fire, electrical shock or explosion may occur if used near combustibles
explosive atmosphere, corrosive air, wet environment or submerged in fluid.
!
Caution! Fire, electrical shock, injury and damage may
occur if not used in accordance with Fluid Metering, Inc.
specifications and operation instructions.
Do not put wet fingers into power outlet of unit.
Do not operate with wet hands.
Do not operate drive assemblies that require a hard mount
(to be bolted down) unless they are mounted per Fluid Metering.
specifications, if not injury may occur and/or damage to unit.
Do not touch any rotating pump or motor components: injury
may occur.
Do not run pump dry, unless designed for that service.
Running dry is harmful to the pump, and will cause excessive
heating due to internal friction.
Check pump rotation and inlet/outlet pump port orientation
before connecting power to pump. If not injury may occur.
When pulling out cords from outlets do not pull cord, grasp
plug to prevent plug damage or electrical shock.
Fluid Metering, Inc. Drive Motors become HOT and can
cause a burn
. DO NOT TOUCH!
Turn off the electrical power before checking pump for any problems.
Connect motor, speed controllers, or any other electrical devices
based on Fluid Metering Inc. specifications. Any unauthorized work
performed on the product by the purchaser or by third parties can
impair product functionality and thereby relieves Fluid Metering, Inc.
of all warranty claims or liability for any misuse that will cause
damage to product and/or injury to the individual.
Power cables and leads should not be bent, pulled or inserted by
excessive force. Otherwise there is a threat of electrical shock or fire.
Replace any inline fuses only with fuse rating as specified by
Fluid Metering, Inc.
When pump/drive is under operation, never point discharge tubing
into face or touch any rotating components of pump. In a power
down thermal overload cut-in condition, unplug or turn off power
to pump. Always allow a cool down period before restarting:
otherwise, injury or damage may occur.
For 30 seconds after power is removed from pump/drive: do not
touch any output terminals. Electrical shock may occur because of
residual voltage.
!
SAFETY INSTRUCTIONS
!
Figure 1 Figure 2
Seitenansicht 0
1 2 3 4 5 6 7

Inhaltsverzeichnis

Seite 1 - V300 SET UP INSTRUCTIONS

IN-V300-081V300 SET UP INSTRUCTIONS FOR ADDITIONAL REFERENCES SEE H431 AND Q431Before using any Fluid Metering, Inc. product read the following safety

Seite 2 - IN-V300-08

IN-V300-081.0 General DescriptionThe V300 Stroke Rate Controller provides precisionflow control for FMI variable speed "V" Series pumps.The

Seite 3

display. The stroke rate is displayed as a percentageof the fastest rate. If you attempt to go beyond theselimits, the display will show three dashe

Seite 4

cating you are under the limit. (See Figure 2 for cableconnections)To run the V300 system in 4-20 mA mode, simply turnthe Mode Switch to "4-20 mA

Seite 5 - Figure 3

Caution: On power up, the pump will start automatically. Do not turn on the power to the controlmodule unless you are sure that the pump is ready too

Seite 7 - Figure 4

5.75 146.14.0 101.6V300OUTLINEV300MOUNTING TEMPLATEFigure 4

Kommentare zu diesen Handbüchern

Keine Kommentare