Before using any Fluid Metering, Inc. product read the following safety instructions
as well as specific product specifications and operating instructions.
Warning!
Fire, electrical shock or explosion may occur if used near combustibles
e
xplosive atmosphere, corrosive air, wet environment or submerged in fluid.
!
Caution! Fire, electrical shock, injury and damage may
occur if not used in accordance with Fluid Metering, Inc.
specifications and operation instructions.
Do not put wet fingers into power outlet of unit.
Do not operate with wet hands.
Do not operate drive assemblies that require a hard mount
(to be bolted down) unless they are mounted per Fluid Metering, Inc.
specifications, if not injury may occur and/or damage to unit.
Do not touch any rotating pump or motor components: injury may
occur.
Do not run pump dry, unless designed for that service.
Running dry is harmful to the pump, and will cause excessive heating
due to internal friction.
Check pump rotation and inlet/outlet pump port orientation before
connecting power to pump. If not injury may occur.
When pulling out cords from outlets do not pull cord, grasp plug to
prevent plug damage or electrical shock.
Fluid Metering, Inc. Drive Motors become HOT and can cause
a burn
. DO NOT TOUCH!
Disconnect electrical power before checking pump for any problems.
Connect motor, speed controllers, or any other electrical devices
based on Fluid Metering Inc. specifications. Any unauthorized work
performed on the product by the purchaser or by third parties can
impair product functionality and thereby relieves Fluid Metering, Inc.
of all warranty claims or liability for any misuse that will cause
damage to product and/or injury to the individual.
Power cables and leads should not be bent, pulled or inserted by
excessive force. Otherwise there is a threat of electrical shock or fire.
Replace any inline fuses only with fuse rating as specified by Fluid
Metering, Inc.
When pump/drive is under operation, never point discharge tubing
into face or touch any rotating components of pump.
In a power down thermal overload cut-in condition, unplug or turn off
power to pump. Always allow a cool down period before restarting:
otherwise, injury or damage may occur.
For 30 seconds after power is removed from pump/drive: do not
touch any output terminals. Electrical shock may occur because of
residual voltage.
!
2.0 GENERAL SET-UP
2.1 Setting Dispense Stroke Rate
Strokes Per Minute (spm): For fluids of 500cps
viscosity or less a stroke rate of 120-350 spm max is
ideal. For fluids with greater than 500cps a slower rate
is recommended.
2.2 Fluidics:
Inlet (Suction) Tubing: To avoid cavitation use the
most resilient tubing possible with the largest
inside diameter (I.D.)
Outlet (Dispense) Tubing: For best dispense
performance use rigid Teflon tubing (to reduce
peristaltic action) with an equal or smaller I.D. than the
inlet (suction) tubing.
REQUIRED TOOLS:
1. Analytical Pan Balance
2. Hex Key Driver for Adjusting Stroke Length:
STH: 3/32" Hex Driver
STQ: 7/32" Hex Driver
3. A removable wicking thread lock (loctite 290)
1.0 PUMP MOUNTING: For optimum pump per-
formance it is recommended that your FMI pump
be mounted in a vertical position with the pump
head down in a 6:00 o'clock position and the motor
at 12:00 o'clock. This orientation will allow air bub-
bles that enter the pumping chamber to directly exit
through buoyancy assistance. Figure A
Figure A
!
www.fmipump.com [email protected] 800-223-3388 516-922-6050
SAFETY INSTRUCTIONS
IN-ST431-14
STH/Q SET UP INSTRUCTIONS
FOR ADDITIONAL REFERENCES SEE H431 AND Q431
Seitenansicht 0
1 2 3 4 5 6 7

Inhaltsverzeichnis

Seite 1 - STH/Q SET UP INSTRUCTIONS

1Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications and operating instruc

Seite 2 - Flag Edge Approaching Sensor

2.3 Step Motors:FMI ST pumps are supplied with a 17 or a 23frame Motors. For wiring diagram and detailed motor specifications go to the literature se

Seite 3 - IN-ST431-14

The design of FMI Pumps is unique throughout theworld. Having no valves and only one moving part,“the piston” makes this design very special. No valve

Seite 4

With the Pump/Drive Assembly removed from theinstrument and the piston/cylinder group removed(MAY REQUIRE PUMP RECALIBRATION):b) If the pump is severe

Seite 5 - Figure D

IN-ST431-145Figure BFigure C3.0 CALIBRATION AND TESTING3.1 Flush the system: clean with alcohol or other suitable cleaning/wetting agent before using

Seite 6

3.4 Dispense Volume Values for FMI STH/STQPumps:NOTE: To assure the best performance set thepump displacement volume as large as possible. FMI pumps

Seite 7 - Rotational Sensor

IN-ST431-147Figure ENOTE:FOR ADDITIONAL REFERENCES SEE H431 AND Q431VccVcc* NOT SUPPLIED WITH OPTICAL SENSORS See suggested Rd values table below

Kommentare zu diesen Handbüchern

Keine Kommentare