Save this manual for future reference.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas sup
plier, call the fire department.
Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Re-
fer to this manual for correct installation
and operational procedures. For assis-
tance or additional information consult a
qualified installer, service agency, or the
gas supplier.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry,
UL127 factory-built fireplace, or in an ap-
proved ventless firebox. It is design certi-
fied for these installations in accordance
with ANS Z21.11.2. Exception: Do not in-
stall this appliance in a factory-built fire-
place that includes instructions stating it
has not been tested or should not be used
with unvented gas logs.
EMBER MASTER™
OWNER’S OPERATION AND INSTALLATION MANUAL
P
I
L
O
T
O
F
F
O
N
LO
REMOTE
OFF
ON
HI
VFP18R
VFP24R
VFP30R
18", 24", and 30"
Remote-Ready
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED
AS VENTED DECORATIVE APPLIANCES
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
Seitenansicht 0
1 2 3 4 5 6 ... 25 26

Inhaltsverzeichnis

Seite 1 - PROPANE/LP GAS LOG HEATER

Save this manual for future reference.WARNING: If the information in this manualis not followed exactly, a fire or explosionmay result causing propert

Seite 2

10105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.INSTALLING HEATER BASEASSEMBLY WARNING: You must securethis heater to fireplace

Seite 3

11105073OWNER’S MANUALCONNECTING TO GASSUPPLY WARNING: A qualified serviceperson must connect heater to gassupply. Follow all local codes. CAUTION: N

Seite 4

12105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.ONPOSITIOPOSIOpenClosedEquipmentShutoffValveEquipmentShutoff ValvePressure Testi

Seite 5

13105073OWNER’S MANUALBottom MiddleLog (#2)Metal PostMetalPostGrooveGrooveGrateFigure 18 - Installing Bottom MiddleLog (#2)Rear Log (#3)PegGrateProngG

Seite 6

14105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.OFFPILOTONLOIHAUTOOFFON4. Press in and turn control knob clock-wise to the OF

Seite 7

15105073OWNER’S MANUALTO TURN OFF GAS TOAPPLIANCEShutting Off Heater1. Turn control knob clockwise to the OFF position.2a. Set selector switch in the

Seite 8

16105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.OFFPILOTONLOIHONOFFREMOTEOPERATINGHEATERContinuedFigure 24 - Setting the Remote

Seite 9

17105073OWNER’S MANUALCLEANING ANDMAINTENANCE WARNING: Turn off heaterand let cool before cleaning. CAUTION: You must keepcontrol areas, burners, and

Seite 10 - FIREPLACE MANUFACTURERS INC

18105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC. WARNING: Turn off and un-plug heater and let cool beforeservicing. Only a quali

Seite 11 - OWNER’S MANUAL

19105073OWNER’S MANUALREMEDY1. Contact local propane/LP gas company2. Clean burner(s) (see Cleaning and Main-tenance, page 17) or replace burnerorific

Seite 12

2105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.SAFETYINFORMATION DANGER: Carbon monoxidepoisoning may lead to death!Carbon Monox

Seite 13

20105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.REMEDY1. This is common with most heaters. Ifnoise is excessive, contact qualifi

Seite 14

21105073OWNER’S MANUALREPLACEMENTPARTSNote: Use only original replacement parts.This will protect your warranty coverage forparts replaced under warra

Seite 15

22105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.ILLUSTRATEDPARTSBREAKDOWNVFP18RVFP24RVFP30R2967891077241211122213252629291518202

Seite 16

23105073OWNER’S MANUALPARTS LISTVFP18RVFP24RVFP30RThis list contains replaceable parts used in your heater. When ordering parts, follow theinstruction

Seite 17

24105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.Purchase these heater accessories from yourlocal dealer. If they can not supply

Seite 18

25105073OWNER’S MANUALNOTES___________________________________________________________________________________________________________________________

Seite 19

KEEP THIS WARRANTYWARRANTY INFORMATIONAlways specify model and serial numbers when communicating with the factory.We reserve the right to amend these

Seite 20

3105073OWNER’S MANUALFigure 1 - Ember MasterFrontLogsControl KnobRear LogBaseAssemblyFrontBurnerPiezoIgnitorRearBurnerCrossover LogBottomMiddleLogSele

Seite 21

4105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.Today’s homes are built more energy effi-cient than ever. New materials, increase

Seite 22

5105073OWNER’S MANUALDETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this work sheet to determ

Seite 23

6105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.AIR FORCOMBUSTION ANDVENTILATIONContinuedOutletAirVentilatedAttic OutletAirInletA

Seite 24

7105073OWNER’S MANUALLOG SIZING REQUIREMENTSMinimum Firebox SizeLog Front Rear*Size Height Depth Width Width18" 17" 14" 20" 14&quo

Seite 25

8105073UNVENTED PROPANE/LP GAS LOG HEATERFIREPLACE MANUFACTURERS INC.Noncombustible Requirements forMaterial Distance (A) Safe Installation12" or

Seite 26 - WARRANTY INFORMATION

9105073OWNER’S MANUALFigure 7 - Minimum Mantel Clearances When Using HoodContinuedFLOOR CLEARANCESA. If installing appliance on the floor level,you mu

Verwandte Modelle: VFP18R | VFP30R |