For more information, visit www.fmiproducts.com
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
MODELS VSGF36NRC AND VSGF36PRC
UNVENTED (VENT-FREE) GAS FIREPLACE SYSTEM
OWNER’S OPERATION AND INSTALLATION MANUAL
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
PFS
®
US
Hearth
by FMI PRODUCTS, LLC
TM
Vantage
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1

For more information, visit www.fmiproducts.com WARNING: If the information in this manual is not followed exactly, a re or explosion may result caus

Seite 2 - TABLE OF CONTENTS

www.fmiproducts.com121082-01K10 CAUTION: This replace cre-ates warm air currents. These currents move heat to wall sur-faces next to replace. In

Seite 3 - Continued

www.fmiproducts.com121082-01K11INSTALLATIONContinuedMantel Clearances for Built-In InstallationIf placing custom mantel above built-in rebox, you mus

Seite 4 - LOCAL CODES

www.fmiproducts.com121082-01K12Rough Opening Dimensions for Built-in InstallationFront Width(Inside to Inside)HeightDepth (Minimum)41 1/2" 40 1/2

Seite 5 - PRODUCT FEATURES

www.fmiproducts.com121082-01K13INSTALLATIONContinuedINSTALLING FIREBOX USING OPTIONAL ACCESSORY MANTELS WARNING: A qualied service person must insta

Seite 6 - PRODUCT SPECIFICATIONS

www.fmiproducts.com121082-01K14INSTALLATIONContinued WARNING: Never connect natural gas replace to private (non-utility) gas wells. This gas is

Seite 7 - VENTILATION

www.fmiproducts.com121082-01K15Note: If adding the G8007 series brick liner accessory, install it now. Follow instructions in G8007 accessory kit. CA

Seite 8 - FOR HEATER LOCATION

www.fmiproducts.com121082-01K16CHECKING GAS CONNECTIONS WARNING: Test all gas pip-ing and connections, internal and external to unit, for leaks aft

Seite 9

www.fmiproducts.com121082-01K17INSTALLATIONContinuedPRESSURE TESTING FIREPLACE GAS CONNECTIONS1. Open equipment shutoff valve (see Figure 18, pag

Seite 10 - INSTALLATION

www.fmiproducts.com121082-01K18INSTALLING LOGS WARNING: Failure to posi-tion the parts in accordance with these diagrams or failure to u

Seite 11

www.fmiproducts.com121082-01K19INSTALLATIONContinuedFigure 27 - Hood Placement (Model May Vary From Illustration)HARD-WIRING FIREBOXNOTICE: A qualie

Seite 12

www.fmiproducts.com121082-01K2SAFETYTABLE OF CONTENTSSafety ... 2Local Codes...

Seite 13

www.fmiproducts.com121082-01K20OFF PILOT ON OFFHILONOTICE: During initial operation of new replace, burning logs will give o

Seite 14

www.fmiproducts.com121082-01K217. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the

Seite 15

www.fmiproducts.com121082-01K22OPERATIONContinuedHAND-HELD REMOTE OPERATIONBATTERIES WARNING: Make sure your selector switch is in OFF posi-tion befo

Seite 16

www.fmiproducts.com121082-01K23OPERATIONContinuedFLAME HEIGHTThis function allows you to control height of ames through 5 levels (see Figure 36). Se-

Seite 17

www.fmiproducts.com121082-01K24Figure 41 - Correct Pilot Flame PatternPilot BurnerFigure 42 - Incorrect Pilot Flame PatternPilot BurnerThermocouple(Pi

Seite 18

www.fmiproducts.com121082-01K25CLEANING AND MAINTENANCE WARNING: Turn off replace and let cool before cleaning. CAUTION: You must keep control a

Seite 19

www.fmiproducts.com121082-01K26TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualied service person should service a

Seite 20 - OPERATION

www.fmiproducts.com121082-01K27TROUBLESHOOTINGContinuedOBSERVED PROBLEM POSSIBLE CAUSE REMEDYODS/pilot lights but flame goes out when control knob is

Seite 21

www.fmiproducts.com121082-01K28TROUBLESHOOTINGContinuedOBSERVED PROBLEM POSSIBLE CAUSE REMEDYSlight smoke or odor during initial operation.1. Not enou

Seite 22

www.fmiproducts.com121082-01K29TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not

Seite 23

www.fmiproducts.com121082-01K3 WARNING: Do not allow fans to blow directly into replace. Avoid any drafts that alter burner ame patterns. Ceilin

Seite 24 - INSPECTING BURNERS

www.fmiproducts.com121082-01K30SPECIFICATIONSFigure 47 - Remote Control Wiring DiagramBlack ConnectorsReceiverTo ThermopileWhiteRedModel VSGF36NRC• R

Seite 25 - CLEANING AND MAINTENANCE

www.fmiproducts.com121082-01K31REPLACEMENT PARTSACCESSORIESPurchase these rebox accessories from your local dealer. If they can not supply these

Seite 26 - TROUBLESHOOTING

www.fmiproducts.com121082-01K32PARTSMODELS VSGF36PRC, VSGF36NRC231719 1512121411162425183120 (NG Only)21(NG Only)3334382714133226LPG722286243 (NG Only

Seite 27

www.fmiproducts.com121082-01K33PARTSThis list contains replaceable parts used in your rebox. When ordering parts, follow the instruction

Seite 28

www.fmiproducts.com121082-01K34PARTSMODELS VSGF36PRC AND VSGF36NRC1487627910281112221829252620172119161513523142324

Seite 29

www.fmiproducts.com121082-01K35KEYNO. PART NO. DESCRIPTION QTY.1 113190-01CK Screen 22 116865-01CK Bottom Louver Assembly 13 ** Face Weldment 14 1013

Seite 30 - TECHNICAL SERVICE

121082-01Rev. K01/11WARRANTYKEEP THIS WARRANTYFMI PRODUCTS, LLC LIMITED WARRANTIESNew ProductsStandard Warranty: FMI PRODUCTS, LLC warrants this new p

Seite 31 - ACCESSORIES

www.fmiproducts.com121082-01K41. This appliance is only for use with type of gas indicated on rating plate. This appliance is not convertible for use

Seite 32 - MODELS VSGF36PRC, VSGF36NRC

www.fmiproducts.com121082-01K5Remote ControlPRODUCT IDENTIFICATIONFigure 1 - Log Base AssemblyLog SetBase AssemblyFront BurnerRear BurnerTop Louver As

Seite 33 - VSGF36NRC

www.fmiproducts.com121082-01K6 LOCATING FIREBOXFigure 3 - Firebox DimensionsFirebox Top View Front View Right Side View Left Side ViewPLANNING Pla

Seite 34 - 121082-01K

www.fmiproducts.com121082-01K7AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a room or space unless the requi

Seite 35 - NO. PART NO. DESCRIPTION QTY

www.fmiproducts.com121082-01K8AIR FOR COMBUSTION AND VENTILATIONContinuedDETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Conn

Seite 36 - WARRANTY

www.fmiproducts.com121082-01K9VENTILATION AIRVentilation Air From Inside Building This fresh air would come from an adjoining unconned space. When